We are here to help.
Our dedicated staff in Boerne, Texas is available to answer questions about Electrolab products and services.
For more info, call:
1 888 301-2400
Monday-Friday: 7am-4:30pm Central Time
Categories: Level Sensors
The Model 2100 DLS with High-Level Shut-In delivers consistently accurate measurements of different types of fluids in both hazardous and non-hazardous environments. Multiple fluid densities and temperatures do not affect the measurements. The DLS with High-Level Shut-In effectively measures the level and temperature of a variety of liquids, including Crude oil, Diesel, Kerosene, Condensate, Gasoline, Water, and Others.
With the addition of a third float, the Model 2100 DLS with High-Level Shut-In provides two digital outputs, one for a high-level alarm and one for a high-high level shut-in. This is all accomplished with two distinct circuits: one for normal continuous level and temperature measurement and the other for high-level alarm and shut-in. The high-level alarm requires no power and, unlike competitor’s sensors, is not affected by power outages. The high-level alarm and shut-in feature are always active.
(Please include all of the specifications from the Configuration Options below on your RFQ)
ACCURATE AND VERSATILE
The Model 2100 DLS with High-Level Shut-In delivers consistently accurate measurements of different types of fluids in both hazardous and non-hazardous environments. Multiple fluid densities and temperatures do not affect the measurements. The DLS with High-Level Shut-In effectively measures the level and temperature of a variety of liquids, including Crude oil, Diesel, Kerosene, Condensate, Gasoline, Water, and Others.
These digital level sensors are suitable for production monitoring, inventory control, leak detection (in stagnant tanks), high-level alarm and well shut-in. Communications to SCADA systems can be digital or analog and the DLS works with many wireless systems using Modbus RTU protocols and ASCII.
With the addition of a third float, the Model 2100 DLS with High-Level Shut-In provides two digital outputs, one for a high-level alarm and one for a high-high level shut-in. This is all accomplished with two distinct circuits: one for normal continuous level and temperature measurement—the other for high-level alarm and shut-in. The high-level alarm requires no power and, unlike competitor’s sensors, is not affected by power outages. The high-level alarm and shut-in feature are always active.
By adding an integrated test device to the Model 2100 DLS, it allows for testing of the high-level shut-in feature at any time and provides the added safety benefit of not having to open the tank hatch. A Teflon-coated string attached to the third float provides a means to manually raise the float and trigger the high-level output/alarm.
Resolution: ½ inch (+/- ¼ inch), +/- ¼ inch (+/- 1/8 inch)
# Floats: One float for product level, one float for water interface and high-level, one float for high-level shut-in
Digital Output Trigger Settings: For 1/4", 9.5' from the top of the measurement scale, for 1/2", 11" from the top of the measurement scale, High-High alarm allows for complete shut-in within 4" of the top of the measurement scale
Communication Options: Hardwire (RS-485, 4-20mA signal), Wireless
Protocols: Modbus RTU 16-bit, Modbus RTU 32-bit, Serial via ASCII, Modbus RTU 2 x 16-bit
Wiring: 16-18 AWG recommended for Digital Circuits
Tubing Material: 316L Stainless Steel (18 gauge)
Measurement Length: 2-35 feet
Composition of fluid to be measured inside tank: Water, oil, gas, diesel, kerosene, condensate and others